Question 1What does the classical equal-area criterion compare?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage and current magnitudesB.Accelerating and decelerating energy areasC.Real and reactive lossesD.Positive and zero sequence currents
Question 2Why does faster fault clearing generally help first-swing rotor stability?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It reduces fault-on acceleration timeB.It guarantees zero post-fault power transferC.It increases rotor inertia instantlyD.It increases the fault duration
Question 3Ignoring damping, what happens when mechanical input power exceeds electrical output power in the swing equation?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Speed remains constantB.The rotor deceleratesC.The rotor acceleratesD.Excitation becomes zero
Question 4What distinguishes transient rotor-angle stability?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Ability to maintain cable color codingB.Accuracy of tariff meteringC.Ability to maintain synchronism after a large disturbanceD.Constant current under every voltage change
Question 5What does a larger inertia constant generally do for a given initial accelerating power?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reduce the initial accelerationB.Eliminate the disturbance entirelyC.Increase the acceleration in direct proportionD.Set acceleration independently of torque
Question 6What does critical clearing time mean for a specified fault and post-fault network?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Time from fault inception to relay pickupB.Breaker opening time after receipt of a trip commandC.Time from fault inception to the first rotor-angle peakD.Maximum clearing time that preserves stability
Question 7What does a power system stabilizer add to excitation control?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A signal to hold prime-mover power constantB.A signal to damp rotor oscillationsC.A constant field-current offset at every operating pointD.A signal to limit sustained field current to its thermal rating
Question 8For a simple lossless two-bus transfer P = Pmax sin δ, where is the static power-angle maximum in the first half cycle?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.45°B.180°C.0°D.90°
Question 9Which condition can put a heavily loaded area at risk of voltage instability?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Exhausted reactive support and declining voltageB.Synchronous frequency alone regardless of reactive balanceC.Abundant local reactive reserve at every busD.Exactly zero reactive demand permanently
Question 10How can fast excitation improve post-disturbance system behavior?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Physically shorten transmission linesB.Remove generator inertiaC.Increase every clearing time deliberatelyD.Support voltage and power transfer during recovery