Question 1What does a shunt reactor absorb to reduce light-load overvoltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reactive powerB.FrequencyC.Sustained mechanical powerD.Field current directly
Question 2What does a series capacitor do to inductive line reactance at power frequency?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Eliminates the need for insulationB.Increases conductor resistanceC.Reduces net series reactanceD.Unconditionally increases net reactance
Question 3How can a STATCOM operating capacitively support a local bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Inject reactive currentB.Permanently absorb all real powerC.Increase overhead line clearanceD.Replace the frequency governor
Question 4In a predominantly inductive line, real power flow is most strongly affected by which difference under standard decoupling assumptions?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Relay pickup currentB.Only the voltage magnitudes in all casesC.Only conductor temperatureD.Voltage phase angle
Question 5What change primarily helps local low voltage in an inductive distribution network?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Absorb more vars at the weak busB.Disable all voltage regulationC.Raise all line resistanceD.Supply reactive power near the weak bus
Question 6What is an advantage of a STATCOM over a fixed capacitor at reduced bus voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It can regulate current within converter limitsB.It consumes all local real power to operateC.Its output current must drop in proportion to voltageD.It supplies unlimited current
Question 7Why disconnect a capacitor stage after load decreases sharply?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Increase stored charge indefinitelyB.Force an undervoltage eventC.Raise capacitive injectionD.Avoid excessive bus voltage or leading power factor
Question 8For a fixed shunt capacitor, how does reactive power output change if voltage falls to 0.9 pu?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It becomes 0.90 of nominalB.It becomes 1.11 of nominalC.It remains fixedD.It becomes 0.81 of nominal
Question 9What trade-off should be assessed when installing series capacitors in a transmission corridor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Higher transfer capability with no change to relay reachB.Higher transfer capability versus resonance and protection effectsC.Higher line reactance versus lower thermal conductor ratingD.Lower line resistance versus higher fundamental-frequency reactance
Question 10Why coordinate tap control with reactive compensation?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Make both devices act on every minor voltage deviationB.Force taps and capacitor stages to switch in opposite directionsC.Make tap position respond directly to power factor aloneD.Maintain voltage and reserve without control hunting