Question 1What is specified at a PV bus in conventional load flow?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage magnitude and angleB.Active and reactive powersC.Active power and voltage magnitudeD.Reactive power and voltage angle
Question 2What off-diagonal Y-bus entry comes from a single series admittance y between two buses with no taps?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.−yB.+yC.1/yD.0
Question 3What does the slack bus provide in conventional load flow?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Fixed P and Q at all busesB.Loss-free operationC.Zero voltage angle at every busD.A reference angle and balancing power
Question 4Which quantities are specified at a PQ bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Active and reactive powerB.Reactive power and angleC.Voltage magnitude and angleD.Active power and voltage magnitude
Question 5What voltage quantities are solved at a standard PQ bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Neither voltage quantityB.Magnitude and angleC.Only voltage magnitudeD.Only frequency and pole count
Question 6What is typical when a PV generator bus reaches a reactive limit?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Set its angle to the slack reference permanentlyB.Remove every connected lineC.Ignore the limit and force rated field currentD.Fix Q at the limit and solve the bus as PQ
Question 7A bus connects to two untapped branches with admittances j2 and j3 S and no shunt. What is its Y-bus diagonal?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.−j5 SB.j6 SC.j1 SD.j5 S
Question 8What does the Gauss–Seidel method use as soon as a new bus voltage becomes available?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.No values from earlier busesB.Only the original flat-start value foreverC.The updated value in subsequent bus equationsD.A voltage from a different network
Question 9What matrix does Newton–Raphson use to map power mismatch into voltage corrections?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Identity in every operating conditionB.A fault-current symmetrical component matrixC.Transformer vector-group matrix onlyD.Jacobian
Question 10What is a typical convergence test for a power-flow solution?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Every bus meets both P and Q targets irrespective of bus typeB.Every voltage update is zero even if residuals remain largeC.Power mismatches fall below tolerance in the solved equationsD.Every bus voltage equals its nominal value