Question 1What is the function of a transformer surge arrester?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Provide sustained fault interruptionB.Increase the surge crestC.Carry normal load currentD.Limit surge voltage by diverting surge current
Question 2Why place an earth wire above overhead phase conductors?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Raise line-to-earth voltageB.Tune power-frequency resonanceC.Intercept direct lightning strikesD.Carry normal phase load current
Question 3Why keep transformer surge arrester leads short and direct?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Increase normal operating currentB.Raise phase-to-phase voltageC.Reduce inductive voltage rise during steep surgesD.Block the surge path to earth
Question 4What initiates a typical cloud-to-ground lightning channel toward earth in a negative flash?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A stepped leader descending from the cloudB.A steady power-frequency current through insulationC.A transformer winding resonance aloneD.A mechanical conductor vibration
Question 5Why can lightning near a line cause a surge without directly striking it?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The line has zero inductanceB.Direct current always enters the neutralC.Electromagnetic coupling induces voltage on conductorsD.Nearby lightning cannot influence conductors
Question 6What property identifies a metal-oxide surge arrester's behavior?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Constant open circuit at all voltagesB.Strongly nonlinear voltage-current characteristicC.Constant zero resistance at service voltageD.Linear current at all voltages
Question 7Why coordinate an arrester's protective level with equipment insulation withstand?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Eliminate load currentB.Keep surge stress below insulation capability with marginC.Make the arrester protection level higher than any insulationD.Raise system frequency
Question 8What can cause backflashover after a strike to an overhead tower?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Phase spacing becomes infiniteB.The tower remains at perfect zero potential irrespective of currentC.Only the transformer fuse meltsD.Tower potential rises enough to flash across an insulator to a phase
Question 9What side effect does a shield wire's grounding provide for a direct strike to the wire?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A deliberate rise in insulation stress on every spanB.Conversion to normal balanced load currentC.No need for tower footing designD.A route for lightning current through supports to earth
Question 10Which parameter is especially important for steep lightning-surge lead voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Bus phase labelB.Steady-state bearing frictionC.Power-frequency real energy priceD.Lead inductance