Question 1What is step voltage during an earth fault?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage between ground points one step apartB.Voltage between grounded enclosure and ground at the feetC.Voltage between the faulted phase and system neutralD.Voltage between an electrode and a distant earth point
Question 2What is touch voltage during an earth fault?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage between ground points one step apartB.Voltage between the grounded neutral and a phase conductorC.Voltage between an electrode and remote earthD.Voltage between touched metal and ground at the feet
Question 3What is a purpose of protective bonding of an exposed conductive enclosure?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Carry normal return current through the enclosureB.Raise enclosure resistance to prevent protective trippingC.Provide a fault path and limit touch voltageD.Break electrical continuity between adjacent metal parts
Question 4What distinguishes system earthing from equipment earthing?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Bond exposed metal versus earth a circuit pointB.Earth a circuit point versus bond exposed metalC.Bond a line conductor versus bond a neutral conductorD.Protect against overload versus interrupt short circuits
Question 5Why test soil resistivity before designing an earth grid?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It affects electrode resistance and surface potentialsB.It eliminates the need for conductor sizingC.It fixes transformer vector groupD.It determines grid frequency
Question 6Which measurement method is widely used for soil resistivity with four equally spaced probes?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Wenner methodB.Open-circuit transformer testC.Nyquist testD.Two-wattmeter method
Question 7How can a high-resistivity surface layer such as crushed rock improve substation safety?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Replace the grounding gridB.Make earth-fault current always zeroC.Increase foot contact resistanceD.Reduce transformer losses directly
Question 8Why bond adjacent exposed metal parts likely to be touched together?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reduce potential difference between themB.Make insulating clearances irrelevantC.Raise phase currentD.Increase potential difference deliberately
Question 9What is a reason to ground a power-system neutral through resistance?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Allow unlimited ground-fault currentB.Increase normal phase loadingC.Limit ground-fault current to a designed valueD.Eliminate every transient overvoltage
Question 10Why verify isolation and absence of voltage before applying portable earthing under an approved procedure?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Avoid applying an earth directly to an energized conductorB.Replace equipment labelsC.Assume opening a switch always removes all energyD.Increase current through the earth set