Question 1Which protection compares currents at the boundaries of a protected zone?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.UnderfrequencyB.DifferentialC.UndervoltageD.Reverse power
Question 2What does a basic distance relay estimate from its voltage and current?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Apparent impedanceB.Conductor temperatureC.Oil acidityD.Rotor speed
Question 3With unchanged settings, how does a larger fault current affect a typical inverse-time overcurrent relay delay?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It always becomes exactly zeroB.It becomes unrelated to pickup multipleC.It increasesD.It decreases
Question 4What does relay pickup current specify?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The CT core temperatureB.The breaker interrupting ratingC.The contact interruption timeD.The current threshold for initiation of operation
Question 5Why grade a downstream relay faster than its upstream backup for the same downstream fault?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Change the supply frequencyB.Preserve selective clearingC.Block backup indefinitelyD.Increase the area disconnected
Question 6What quantity does a residual earth-fault element obtain by summing three phase currents?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Residual current, equal to 3I₀B.Positive-sequence current I₁C.Negative-sequence current I₂D.Per-phase zero-sequence current I₀
Question 7What helps transformer differential protection avoid tripping for inrush?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Increasing feeder loadB.Ignoring every differential current permanentlyC.Disabling all CT inputsD.Harmonic restraint or blocking
Question 8What is a key difference between a contactor and a fault-rated breaker?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A breaker cannot be remotely trippedB.A contactor always interrupts every prospective fault by itselfC.A breaker is only a voltage sensorD.A contactor usually needs separate short-circuit protection
Question 9Why include backup protection?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Clear the fault before correctly operating primary protectionB.Extend the primary protection coverage with no second trip pathC.Duplicate the alarm without issuing a tripD.Clear faults if the primary relay or breaker fails
Question 10What does undervoltage protection detect?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage below a setting for the required delayB.A loss of lubricantC.Frequency above nominal onlyD.Current above a setting only