Question 1A breaker is rated to break 25 kA and the comparable prospective fault is 31.5 kA. Is it adequate on its own?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Yes, the rating exceeds the faultB.Yes, if its voltage rating is below system voltageC.Yes, with zero pre-fault loadD.No, its breaking rating is too low
Question 2What helps a vacuum breaker extinguish an AC arc after current zero?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Rapid dielectric recovery of the gapB.Compressed air blastC.Oil cooling of the contactsD.Increasing metal vapor density
Question 3After interrupting an AC fault, what must an open breaker gap withstand?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Only the pre-fault load currentB.Core lossC.Transient recovery voltageD.Conductor sag
Question 4What is the function of a breaker trip coil?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Release the operating mechanism on a trip commandB.Carry normal load through the control circuitC.Charge the closing spring mechanically by itselfD.Measure power factor
Question 5Which thermal-magnetic breaker element responds rapidly to high fault current?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Auxiliary status switchB.Manual handle aloneC.Thermal bimetal aloneD.Magnetic trip
Question 6What does thermal protection primarily respond to?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Sustained overload heatingB.Only open contactsC.Enclosure colorD.Neutral voltage phase angle
Question 7What does primary injection testing of a breaker assembly verify?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Test the relay inputs by secondary injectionB.Measure dielectric strength of the open contactsC.Test the primary current path and trip chainD.Time the closing mechanism from a manual command
Question 8Why inspect breaker opening time?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Find ambient humidity aloneB.Measure transformer turns ratioC.Confirm expected clearing speed and pole behaviorD.Determine economic dispatch
Question 9What does rated making current address?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Opening and interrupting the rated fault currentB.Carrying rated load current without overheatingC.Carrying short-circuit current for a specified timeD.Closing onto a fault and withstanding peak current
Question 10Which gas is traditionally used in many high-voltage gas circuit breakers as insulation and arc-quenching medium?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Helium onlyB.HydrogenC.SteamD.SF₆