Question 1Why insert a series reactor in a feeder?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Provide an isolating contact gapB.Eliminate line resistanceC.Limit prospective fault currentD.Increase prospective fault current
Question 2Why open a conventional off-load isolator after a breaker?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The isolator raises the breaker ratingB.The isolator automatically clears short circuitsC.The isolator is designed for isolation after current interruptionD.The isolator changes grid frequency
Question 3What ultimately interrupts current in a cartridge fuse operating normally on an overcurrent?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The melted element lowers resistance and diverts currentB.The element melts and a spring resets the linkC.The element melts and the arc is extinguishedD.The filler opens the circuit while the element stays intact
Question 4What does fuse I²t characterize?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Thermal let-through during operationB.Grid voltage ratioC.Continuous load energy in kWhD.Isolation distance
Question 5Why are current-limiting fuses useful for high prospective faults?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.They prolong fault current deliberatelyB.They reduce actual fault-current peakC.They increase source voltageD.They require no interrupting rating
Question 6What is a replaceable fuse link rated to carry normally?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Only zero currentB.Its maximum breaking current continuouslyC.Its specified continuous current under stated conditionsD.Any current below prospective fault level
Question 7Why choose a time-delay fuse for a suitable motor branch?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Increase rotor resistanceB.Disable overload protection foreverC.Tolerate short starting inrushD.Prevent motor inrush physically
Question 8What does an earth switch do on an isolated feeder?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Interrupt normal feeder load currentB.Establish the feeder isolation gap itselfC.Energize the feeder through the bypass busD.Earth the isolated conductors
Question 9At 50 Hz, what is reactance of a 10 mH series reactor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.3.14 ΩB.0.314 ΩC.31.4 ΩD.0.01 Ω
Question 10What must remain coordinated when replacing a fuse in a protected assembly?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage, enclosure rating and contact resistance onlyB.Rated current and physical dimensions onlyC.Voltage, breaking capacity and time-current curveD.Breaking capacity and physical fit alone