Question 1What is the normal load supply path in an online double-conversion UPS?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Battery wired directly to the AC loadB.Rectifier, DC link, inverterC.Input through a fuse onlyD.Mechanical governor directly to load
Question 2What is the sending-end role of a rectifier station in an HVDC link?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Set receiving frequency using a transformer ratioB.Turn DC into mechanical powerC.Convert AC to DCD.Convert DC to AC during normal sending operation
Question 3Which HVDC layout exchanges power between two AC grids without a long DC transmission line?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Shunt reactor aloneB.Synchronous condenser aloneC.Back-to-back convertersD.Overhead earth wire
Question 4What normally happens during a mains outage in an online UPS?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The input rectifier generates power from an open lineB.All output must stop for manual restartC.Its battery supplies the DC link while inverter operation continuesD.The battery connects directly to an AC load
Question 5What is a UPS static bypass intended to do?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Route battery DC around the inverterB.Route suitable AC around the inverterC.Feed the rectifier from the inverter outputD.Transfer the load from AC directly onto the DC bus
Question 6Why check both kVA and kW ratings when selecting a UPS?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Apparent and real load limits can differB.They describe the same limit for every loadC.Only kVA determines battery voltageD.Real power is irrelevant to converter sizing
Question 7A UPS supplies 600 W from a battery with 480 Wh usable energy at 90% conversion efficiency. Estimate runtime.Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.48 minB.72 minC.43.2 minD.90 min
Question 8Which converter technology can independently control active and reactive power within its current limit in VSC-HVDC?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Mechanical speed governorB.Uncontrolled diode bridge aloneC.DC isolator aloneD.Voltage-source PWM converter
Question 9Why use a smoothing reactor on a DC link in a line-commutated HVDC system?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Filter AC bus voltage by shunt capacitanceB.Increase reactive supply at the AC terminalC.Reduce ripple in the DC line currentD.Suppress DC voltage ripple with a shunt capacitor
Question 10What commonly provides commutation voltage for a line-commutated HVDC inverter?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.An overhead earth wireB.A UPS battery without an inverterC.A passive DC line terminal onlyD.The receiving AC network