Question 1What defines a black-start unit?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It operates only at nightB.It always requires a live busC.It can never supply auxiliariesD.It can start without external grid power
Question 2What must be verified before closing a starting generator onto an energized bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.That the live bus voltage is zeroB.That all other generators are stoppedC.Only reservoir levelD.Synchronism with the bus
Question 3Why establish oil pressure before cranking a generating set designed for prelubrication?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Set generator phase sequenceB.Raise incoming bus voltageC.Protect bearings during startingD.Replace the governor
Question 4Why verify the generator output breaker is open before run-up to a live bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Force frequency to zeroB.Prevent unsynchronized connectionC.Increase rotor inertiaD.Bypass all permits
Question 5Which equipment commonly supplies essential controls during a station blackout?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reactive compensation bank aloneB.Main alternator at standstillC.Station DC battery and its distributionD.An unenergized grid-fed receptacle
Question 6What does a speed governor stabilize before synchronization?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Field current and terminal voltageB.Stator voltage magnitude and reactive outputC.Phase order and transformer tap positionD.Shaft speed and generated frequency
Question 7What interlock can prevent starting a water turbine when bearing lubrication is unavailable?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Minimum bearing oil temperature provenB.Oil reservoir level above its low alarmC.Cooling-water pressure above its trip levelD.Minimum bearing oil pressure proven
Question 8Why energize restoration loads in increments after a black start?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Eliminate system inertiaB.Allow out-of-phase closureC.Make the unit absorb all available powerD.Avoid excessive frequency and voltage disturbances
Question 9What should be checked before admitting water to a hydro unit during normal start?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Generator load and power factor targetsB.Synchronization indications taken after run-upC.The penstock pressure reading aloneD.Waterway and auxiliary start permissives
Question 10What is a spinning generator's dead-bus closing condition distinct from live-bus synchronization?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Verified de-energized target bus and authorized dead-bus logicB.Disable all breaker interlocksC.Close whenever shaft speed is above ratedD.Assume phase matching to an unknown live supply