Question 1Which quantity does an AVR adjust in automatic alternator terminal-voltage control?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Main-field excitation currentB.Governor speed setpointC.Active-power dispatch setpointD.Synchronizer phase reference
Question 2What provides DC to the main field in a typical brushless excitation system?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Rotating rectifierB.Stationary thyristor bridge feeding the main rotor through slip ringsC.DC commutator and brushes supplying the main fieldD.Permanent-magnet pilot exciter connected directly to the field without rectification
Question 3What supplies DC field power in a typical static excitation system?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Rotating diode bridge on the shaftB.Shaft-driven DC commutator exciterC.Freewheel diode branch aloneD.A stationary controlled rectifier
Question 4What signal is compared with voltage reference by the AVR?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Measured generator active powerB.Sensed generator terminal voltageC.Measured generator reactive powerD.Measured rotor field current
Question 5What is field flashing used for?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Limit sustained rotor current under heavy reactive exportB.Build initial field when residual flux is too lowC.Correct terminal-voltage error during steady operationD.Match generator and bus phase angles before closing
Question 6What distinguishes a DC commutator exciter?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It produces field DC solely with stationary thyristorsB.It uses rotating diodes rather than a commutatorC.It provides DC through mechanical commutationD.It provides AC directly to the main field
Question 7What does an overexcitation limiter primarily protect against?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Loss of synchronism from insufficient fieldB.Sustained excessive field heatingC.Rotor heating from negative-sequence stator currentD.Core overfluxing due to excessive volts per hertz
Question 8What can an underexcitation limiter help avoid?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Excessive rotor field current during reactive exportB.Core overfluxing from high volts per hertzC.Operating beyond the underexcited stability or heating limitD.Reverse active power after loss of prime-mover input
Question 9During no-load operation, what happens to generated voltage if speed is fixed and unsaturated field current increases?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It falls in proportion to field currentB.It stays fixed because shaft speed is constantC.It generally increasesD.It only increases if shaft speed also increases
Question 10What is one advantage of an AVR supplied by a separate permanent-magnet generator?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It feeds all main rotor current directly without rectificationB.It makes the AVR supply exactly proportional to main terminal voltageC.Excitation control has a source during a main voltage dipD.It removes the need to limit field current