Question 1A four-pole 50 Hz induction motor runs at 1440 rpm. What is its slip?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.4%B.2%C.8%D.6%
Question 2What is rotor current frequency at 3% slip with a 50 Hz supply?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.3 HzB.16.7 HzC.1.5 HzD.50 Hz
Question 3Why use star-delta starting for a motor rated to run in delta at the supply voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reduce line starting currentB.Eliminate transition transientsC.Increase starting torque over direct deltaD.Raise starting voltage per winding
Question 4What happens to the ideal induction motor rotor EMF at synchronous speed?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It changes to supply frequencyB.It becomes zeroC.It is twice ratedD.It equals starting EMF
Question 5What is the main purpose of a blocked-rotor test?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Determine rotor speed at rated loadB.Measure rated-speed windage aloneC.Find synchronous machine excitationD.Estimate equivalent series impedance and load loss
Question 6What does an induction motor no-load test mainly help estimate?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Magnetizing branch and rotational lossesB.Locked-rotor starting current directlyC.Protection relay grading marginD.Full-load shaft torque directly
Question 7As rotor resistance increases in a wound-rotor motor, where does peak torque occur approximately?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.At lower slipB.Exactly at synchronous speedC.At higher slipD.At unchanged slip under all conditions
Question 8An induction motor air-gap power is 20 kW at 5% slip. What is rotor copper loss?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.19 kWB.1 kWC.0.25 kWD.4 kW
Question 9Why does an induction-motor VFD maintain roughly constant V/f in the constant-flux region below base speed?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Make rotor resistance zeroB.Remove all inverter harmonicsC.Maintain roughly constant air-gap fluxD.Hold shaft speed fixed
Question 10What is the rotor construction of a squirrel-cage motor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A commutated DC armatureB.Bars shorted by end ringsC.Permanent stator magnets onlyD.An open three-phase winding at all times