Question 1What shaft speed gives 50 Hz from a four-pole alternator?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.750 rpmB.3000 rpmC.1000 rpmD.1500 rpm
Question 2How is a synchronous motor operated to supply reactive power as a condenser?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Without a field supplyB.UnderexcitedC.At twice synchronous speedD.Overexcited
Question 3What must match before connecting an alternator to a live bus?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Voltage, frequency, power factor and angleB.Voltage, speed, reactive power and angleC.Voltage, frequency, phase sequence and angleD.Frequency, phase sequence, active power and torque
Question 4A 12-pole alternator runs at 500 rpm. What frequency is generated?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.50 HzB.25 HzC.60 HzD.100 Hz
Question 5On an infinite bus, increasing prime-mover torque mainly increases what?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Stator pole countB.Bus voltage without limitC.System frequency permanentlyD.Active power output
Question 6On a stiff bus, increasing a generator's field excitation at fixed shaft input primarily changes what?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Pole countB.Grid frequencyC.Reactive power exchangeD.Shaft speed
Question 7Why distribute an alternator winding across several slots per pole per phase?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Improve waveform and reduce selected harmonicsB.Make frequency independent of speedC.Eliminate all induced EMFD.Remove the need for a rotor field
Question 8What does short-pitching a winding do to its fundamental pitch factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Makes the fundamental frequency zeroB.Keeps it exactly unity for every pitchC.Makes it greater than unityD.Makes it less than unity
Question 9What can damper bars do during synchronous motor starting?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Open the stator circuitB.Provide induction starting torqueC.Generate field DC directlyD.Make the motor operate forever at standstill
Question 10What is alternator voltage regulation at fixed speed and excitation for 242 V no-load and 220 V loaded?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.22%B.110%C.10%D.9.09%