Question 1What does correctly sized shunt capacitance at an inductive load reduce upstream?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Grid frequencyB.The load terminal voltage to zeroC.The load's real energy requirementD.Reactive current
Question 2A 100 kW sinusoidal load has a lagging displacement power factor of 0.8. What ideal shunt compensation corrects it to unity?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.75 kvarB.80 kvarC.25 kvarD.125 kvar
Question 3For the same current and power-factor magnitude, what happens to the reactance term of approximate feeder voltage drop at leading power factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It subtracts from the resistive termB.It becomes independent of XC.It always adds to the resistive termD.It always equals an infinite drop
Question 4Which device adjusts a feeder's ratio automatically in discrete steps?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Earth gridB.Step-voltage regulatorC.Fixed fuseD.Lightning shield wire
Question 5What risk can fixed capacitors create at very light load?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Overcompensation and possible voltage riseB.Automatic unity power factor under every conditionC.Lower voltage regardless of conditionsD.Complete cancellation of all harmonics
Question 6Why use switched capacitor stages?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Remove protective switchingB.Make compensation constant by designC.Increase peak reactive importD.Match compensation to changing demand
Question 7What reactive correction is needed for 60 kW at tan φ = 0.75 to reach tan φ = 0.25?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.45 kvarB.15 kvarC.60 kvarD.30 kvar
Question 8What can capacitor installation do if supply inductance resonates near an existing harmonic?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Force harmonic frequencies to zeroB.Amplify harmonic current or voltageC.Prevent resonant behavior by definitionD.Remove all harmonics without limits
Question 9Why prefer compensation near a large inductive load when practical?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It always removes the need for an earth pathB.It raises feeder current everywhereC.It raises the motor's kW requirementD.It reduces reactive current in more upstream conductors
Question 10A balanced feeder has receiving voltage of 380 V against a 400 V nominal target. What is the shortfall relative to target?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.5%B.95%C.5.26%D.20%