Question 1What is load factor over a specified period?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Peak divided by averageB.Average load divided by peak loadC.Reactive divided by real powerD.Connected load divided by energy used
Question 2A facility uses 720 kWh per day and peaks at 60 kW. What is its daily load factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.0.75B.0.90C.0.50D.0.30
Question 3What is summed individual maximum demand divided by coincident group peak called?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Capacity factorB.Load factorC.Power factorD.Diversity factor
Question 4What is demand factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Sum of individual peaks divided by group peakB.Maximum demand divided by connected loadC.Average divided by peak demandD.Installed plant capacity divided by delivered energy
Question 5A 100 kW connected installation peaks at 65 kW. What is its demand factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.6.5B.0.35C.1.54D.0.65
Question 6Why can identical annual consumption lead to different feeder sizing?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Peak current is independent of loadB.The demand profiles and peaks can differC.Equal energy implies identical maximum currentD.Feeder size is determined only by yearly energy
Question 7What is a coincident peak?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Sum of the separate customer peak demandsB.Largest individual customer's maximum demandC.Peak of the combined demand profileD.Average demand during the highest-energy month
Question 8A 5 MW peak is predicted to grow 10% annually for two years. What is the forecast?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.5.50 MWB.6.05 MWC.7.00 MWD.6.00 MW
Question 9What distinguishes a constant-power load model as voltage falls?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Its current falls proportionally with voltageB.It draws more current for unchanged real power and power factorC.Its current is always zeroD.Its impedance is constant by definition
Question 10Which factor helps forecast seasonal cooling loads?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Annual average load factor without a temperature breakdownB.Winter peak demand assumed unchanged across seasonsC.Installed cooling capacity assumed to run at full load all summerD.Historical cooling demand versus temperature