Question 1An ideal 200/5 A CT carries 120 A primary current. What is the secondary current?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.5 AB.4.8 AC.3 AD.2 A
Question 2Why is an energized current transformer's open secondary hazardous?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.A high secondary voltage can developB.Open secondary prevents primary currentC.Its turns ratio changes to unityD.Primary voltage must fall to zero
Question 3A meter reads 105 V on an ideal 11 kV/110 V voltage transformer. What is primary voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.10.5 kVB.11.55 kVC.110 kVD.1.05 kV
Question 4What does CT burden refer to?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Magnetizing impedance of the unladen CT coreB.Primary circuit impedance upstream of the CTC.Insulation resistance between the windingsD.Secondary load including lead impedance
Question 5Why can CT saturation cause protection errors?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.It permanently changes primary frequencyB.Secondary waveform no longer represents primary current faithfullyC.It makes all primary currents vanishD.It increases every relay's measured voltage accurately
Question 6How does a protection CT typically differ from a metering CT regarding fault current?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Saturates earlier to limit fault current into the relayB.Prioritizes accuracy near rated current over fault-current reproductionC.Maintains fault-current accuracy by assuming a zero secondary burdenD.Retains useful accuracy at higher fault currents
Question 7What load property should be checked against a PT rating?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Frequency meter display colorB.Primary conductor diameter onlyC.Bus support spacingD.Total secondary VA burden
Question 8What can reversed CT secondary polarity do to a differential scheme?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The measured current ratio doubles at all loadsB.The CT ratio remains accurate but the relay pickup setting doublesC.The through currents cancel more accuratelyD.Through current appears as differential current
Question 9What does a 1 A CT secondary offer compared with 5 A for the same lead resistance and corresponding full-scale conditions?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.One fifth the lead burdenB.One twenty-fifth the lead burden in VAC.Five times the lead burdenD.The same lead burden
Question 10Which transformer is normally connected across the system to provide scaled voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Neutral grounding reactorB.Potential transformerC.Series booster aloneD.Current transformer primary in series