Question 1An ideal 230/115 V transformer supplies 8 A secondary current. What primary current does it draw?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.4 AB.16 AC.8 AD.2 A
Question 2In the standard transformer loss model, what is true at maximum efficiency for fixed voltage and power factor?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Copper loss equals core lossB.Core loss equals rated outputC.Copper loss is zeroD.Load voltage equals source voltage
Question 3Why is a typical transformer no-load power factor low?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Terminal voltage is zeroB.The magnetizing current is predominantly reactiveC.Secondary current exceeds rated valueD.Copper loss dominates rated output
Question 4Which loss does a rated-voltage open-circuit test mainly measure?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.External cable lossB.Core lossC.Bearing lossD.Full-load copper loss
Question 5What is inferred from a rated-current short-circuit test at reduced voltage?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Equivalent series impedance and load lossB.Rated no-load magnetizing current onlyC.Oil dielectric strengthD.Vector group alone
Question 6What is the purpose of a silica-gel breather on a conservator transformer?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Cool the core directlyB.Raise oil pressure continuouslyC.Detect differential currentD.Remove moisture from incoming air
Question 7Why laminate transformer cores?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Prevent all hysteresisB.Increase core conductivity across sheetsC.Reduce eddy currentsD.Raise magnetizing current
Question 8What is a key parallel-operation condition for three-phase transformers?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Equal ratings with any phase displacementB.Equal percent impedances with any voltage ratioC.Matching phase sequence with any secondary voltageD.Compatible voltage ratios and phase displacement
Question 9What does a Buchholz relay detect in a conservator-type unit?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Oil temperature above its alarm settingB.A low conservator level sensed by a float thereC.Winding current imbalance measured by CTsD.Internal fault gas or an oil surge
Question 10If full-load copper loss is 800 W, what is copper loss at half rated current?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.200 WB.400 WC.1600 WD.800 W
Question 11A 50 Hz winding has 200 turns and peak sinusoidal flux of 0.01 Wb. Find RMS EMF.Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.100 VB.444 VC.628 VD.222 V
Question 12Which winding is typically concentric and closer to the grounded core in a core-type step-down transformer?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Low-voltage windingB.High-voltage winding in every designC.Neither uses insulationD.Both must occupy the same radial layer