Question 1What is the phase voltage of a balanced star load supplied at 400 V line-to-line?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.400 VB.200 VC.Approximately 231 VD.Approximately 693 V
Question 2Why is neutral current zero in a balanced sinusoidal star load?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.The three current magnitudes add to zeroB.The star point blocks all zero-sequence pathsC.The three current phasors sum to zeroD.Equal phase voltages force each current to zero
Question 3A balanced delta draws 10 A per branch. What is the line current magnitude?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.5.77 AB.17.32 AC.30 AD.10 A
Question 4A balanced delta load sees 415 V between lines. What voltage is across each branch?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.208 VB.719 VC.240 VD.415 V
Question 5A balanced 400 V three-phase load draws 10 A per line at 0.9 power factor. What active power is drawn?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.10.8 kWB.3.60 kWC.6.24 kWD.6.93 kW
Question 6Which change reverses phase sequence?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Reduce all voltages equallyB.Change supply frequency onlyC.Swap any two line conductorsD.Swap the labels on all three cyclically
Question 7A 400 V balanced load draws 20 A at unity power factor. What is its reactive power?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.0 kvarB.8 kvarC.13.86 kvarD.20 kvar
Question 8In a four-wire star, only phase A carries a 7 A fundamental load. What neutral current flows?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.7 AB.0 AC.12.12 AD.4.04 A
Question 9What can happen when the neutral opens on an unbalanced star load?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.Opening the neutral reverses phase sequenceB.Star-point shift unbalances phase voltagesC.Only the line-to-line voltages become unequalD.All phase voltages retain their nominal values
Question 10In a balanced three-wire system, one of two wattmeters reads zero and the other is positive. What is the load power-factor magnitude?Report a question issueTell us what needs checking.Issue typeIncorrect answerMissing or unclear diagramFormatting problemQuestion or explanation unclearOtherDetails (optional)Review and send the email draft in Gmail. Nothing is sent automatically.Open Gmail draft Copy report detailsReports go to hello@licensepreparationnepal.com.A.0.5B.0.707C.1D.0.866